Molded grating depth guide
Choosing 25, 30, 38 or 50 mm Molded FRP Grating
Depth is one field in the panel description, not a ready-made load class. This guide compares common molded rows by pitch, unit mass and panel handling, then shows how the support span, load case and deflection limit turn a depth into a candidate that can actually be checked.
Prepared by
Dengtai Industry
Published
·
Reviewed
A stack of molded panels from our works. Delivered dimensions and surface are confirmed on the order drawing. Photo: Dengtai Industry.
Definitions
Molded Grating Depth, Span, Deflection and Mass
These terms keep a product dimension separate from the structural question and the delivered handling weight.
- Nominal depth or thickness
- The nominal structural depth used to identify a molded grating row. In this guide, 25, 30, 38 and 50 mm mean panel depths, not the thickness of an individual bar wall or the total height of a covered assembly.
- Mesh pitch
- The centre-to-centre distance between bars. A 38 × 38 mm pitch and a 25 × 50 mm pitch are different geometries, so two panels with the same depth do not automatically belong to the same structural family.
- Clear span
- The unsupported distance between bearing faces on two supports. Panel length, support spacing and clear span are different measurements and must not be substituted for one another when matched load data is selected.
- Deflection
- The movement of the panel under load. A panel can remain intact while deflecting more than the project permits. The permitted deflection is a project criterion, not a value supplied universally by the panel depth.
- Unit mass
- The approximate mass of one square metre of a defined panel row. It helps estimate the load the panel adds to the structure and the weight of a finished piece; it is not an allowable-load figure.
- Panel net weight
- The mass of one full panel or finished cut piece. It drives lifting, handling, nesting and packing decisions. A grit surface, a cover layer and the actual finished size change the delivered weight estimate.
- Matched evidence
- Load, deflection or test information that applies to the proposed construction and stated conditions. A report issued for a different depth, mesh, support or test span does not become applicable because it carries the same resin or product family name.
Factory worksheet
25, 30, 38 and 50 mm Molded FRP Grating Rows
The rows below are selected configurations from our product table. Panel mass is calculated from the nominal size and unit mass; a surface, cover or actual cut size changes the delivered weight.
Swipe horizontally to view all columns.
| Depth and factory row | Pitch (c/c) | Unit mass | Estimated nominal-panel mass | What the row tells us before a load check |
|---|---|---|---|---|
| 25 mm | 38 × 38 mm | 12.5 kg/m² | About 55.8 kg for 1220 × 3660 mm | A useful shallow candidate when the actual frame, span and load data fit; our factory record also includes this row in a solar-walkway order. |
| 25 mm | 40 × 40 mm | 10.5 kg/m² | About 46.9 kg for 1220 × 3660 mm | A tree-pit base configuration. It is not a general foot-traffic or vehicle rating just because the mesh and depth are listed. |
| 30 mm | 38 × 38 mm | 16.5 kg/m² | About 73.7 kg for 1220 × 3660 mm | A common factory starting point for construction pedestrian access, subject to the actual span, loading, supports and exposure. |
| 38 mm | 38 × 38 mm | 19.5 kg/m² | About 87.1 kg for 1220 × 3660 mm | A deeper comparing row. Its suitability still comes from the actual support arrangement and matched load and deflection information. |
| 50 mm · standard | 50 × 50 mm | 21.5 kg/m² | About 96.0 kg for 1220 × 3660 mm | A standard 50 mm row with a wider pitch. It is not interchangeable with the separate 50 mm heavy-duty row. |
| 50 mm · heavy duty | 25 × 50 mm | 45.0 kg/m² | About 200.9 kg for 1220 × 3660 mm | A different, much heavier configuration. It needs its own structural evidence, handling plan and support review. |
Selection factors
What to Compare Before Choosing a Molded Grating Depth
Use the same support, load, construction and evidence basis for every depth under review.
Swipe horizontally to view all columns.
| Selection factor | Why depth alone is insufficient | What to provide |
|---|---|---|
| Support arrangement | The clear span and supported edges determine how the panel is being asked to work. | Mark supports, bearing faces, clear spans, joints and any unsupported edge. |
| Load case | A 25 mm panel and a 50 mm panel cannot be compared without the same load type and position. | State pedestrian, point, line, wheel or equipment load with value and contact area. |
| Deflection | A deeper panel may deflect less, but the result depends on the complete construction and span. | Provide the governing limit, including any absolute and span-fraction criterion. |
| Mesh and construction | Same depth can describe different pitch, bar geometry, reinforcement and surface weight. | State both pitches, orientation, resin, surface and whether the row is standard or heavy duty. |
| Mass and handling | A panel can become difficult to lift or install before the structural choice is settled. | Give access limits, lifting method and maximum finished-piece weight. |
| Cuts and openings | Opening bars and reducing a panel to narrow strips can change local support and deflection. | Show cut sizes, datum points, openings and the remaining bearing path. |
| Evidence | A report or catalog table applies only to its stated product and conditions. | Name the required load table, calculation, report or inspection scope. |
Fit check
When a Molded FRP Grating Depth Can Be Quoted
The result is a candidate configuration and a list of checks, not a load class inferred from the depth label.
Specify this if…
- The actual support frame, clear spans, load type and deflection target can be shared before the depth is chosen.
- Two or more depths can be compared using the same pitch, resin, surface, support arrangement and load case.
- The maximum finished-piece weight can be checked against the available lifting and installation access.
- A shallow 25 or 30 mm row is treated as a candidate requiring matched evidence, not as a default walkway rating.
- A 50 mm heavy-duty row can be supported with its own construction information, handling plan and applicable load evidence.
Look elsewhere if…
- The request specifies only a depth and asks for a safe span or capacity without panel data.
- The buyer plans to compare 25, 30, 38 and 50 mm panels by weight per square metre.
- A heavier or denser panel is assumed to be stronger without checking its structural construction and support.
- Grit, a cover or an anti-static layer is being used as evidence of a higher structural class.
- A nominal 1220 × 3660 mm heavy-duty panel is being proposed without checking that it can be handled safely.
A 25, 30, 38 or 50 mm label describes a nominal molded panel depth, not a complete load rating. The depth becomes meaningful only when it is attached to a bar geometry, mesh pitch, resin, surface and set of support and loading conditions. A deeper panel is often useful when the supports, installation depth and project data support it, but the depth number alone cannot show whether the panel is safe or suitable.
That distinction matters especially in our own product range because two 50 mm products can behave like different choices for the buyer. The standard 50 × 50 mm row is listed at 21.5 kg/m², while the separate 25 × 50 mm heavy-duty row is listed at 45.0 kg/m². They share a nominal depth label, but not the same construction, mass, handling requirement or evidence basis.
This guide turns the depth question into a selection worksheet. It compares verified factory rows, explains the cost and handling implications of panel mass, and shows how to move from a support drawing to a candidate that a supplier can actually check.
If the construction family itself is unresolved, compare molded and pultruded grating first. Increasing the depth of a molded panel is only one route; a directional pultruded section may be the relevant alternative when the support layout and span point that way.
Once the depth candidates are shortlisted, use the complete equipment-platform selection sequence to test them against the actual platform boundary, concentrated loads, service openings and supply interfaces.
What the Four Depth Labels Actually Mean
In molded grating, the depth is commonly used as part of the product name. It tells the buyer which overall panel section is being discussed. It does not say how wide the bearing bars are, how far apart the bars are, how the reinforcement is arranged or what load the panel can carry.
The same rule applies to words such as “heavy duty.” A manufacturer may use it for a proprietary construction, a different pitch, a denser bar pattern or a specific load application. It is not a standard rating. Our 50 mm heavy-duty row must therefore be quoted as a different product from the standard 50 mm, 50 × 50 mm row.
Depth, Finished Height and Cover Thickness
For an open molded panel, the nominated depth is usually the overall panel depth. A cover plate, a chequered layer or another bonded top can change the total finished height and mass. That additional height does not automatically turn the base panel into a stronger structural section, so the complete assembly has to be identified.
When a project is tight on installation depth, measure the available space after supports, clips, cover layers and access details are included. A 38 mm open panel does not occupy the same finished envelope as a 38 mm base with a raised cover.
Depth Is Not the Same as Mesh Size
A 38 mm deep panel can have a 38 × 38 mm mesh, a 19 × 19 mm upper mesh or another configuration. Two products described as “38 mm grating” can therefore differ in mass and bar layout. Specify depth and pitch independently.
For fine-mesh configurations, use the mini-mesh thickness guide to keep overall depth, upper and lower mesh, mass, support and deflection in one comparison. The mini vs micro guide resolves names that do not map to a fixed opening.
This also connects to the separate square versus rectangular molded mesh guide. A rectangular product may add a long-way-of-opening direction and a different support consideration even when the nominal depth remains unchanged.
For a comparison that starts with the project’s load, span, mesh and finished geometry rather than this page’s molded depth rows, use the FRP grating thickness selection guide.
How Our Factory Rows Differ
The factory rows below are good examples of why a buyer should not compare only the first number in the product name.
25 mm Rows
Our 25 mm family includes a 38 × 38 mm pitch row at 12.5 kg/m² and a separate 40 × 40 mm tree-pit base at 10.5 kg/m². The tree-pit configuration is a specific application product, not a general platform rating. A 25 mm row can be the right starting point for a shallow frame, but the actual span and support arrangement still govern.
A configured solar-walkway order in our factory record used 25 mm molded grating, 38 × 38 mm mesh, a grit surface and pieces cut to 400 × 2000 mm. That establishes the row as one available configuration, not a universal suitability statement for every solar-site support system.
30 mm Rows
Our 30 mm, 38 × 38 mm row is listed at 16.5 kg/m². We also use 30 mm molded grating with 38 × 38 mm mesh as a starting point for construction pedestrian access in our selection experience.
That starting point still has to be checked against the actual clear span, equipment or trolley use, required deflection, support condition and environment. It is a candidate for review, not a blanket pass for every construction walkway.
38 mm Rows
Our 38 mm, 38 × 38 mm row is listed at 19.5 kg/m². It is a deeper comparable row in the range, but extra depth alone does not make the row better for every project.
The support frame may have a fixed installation depth. A deeper panel could require a different frame or reach, while a well-supported 30 mm panel may be more practical. The choice should include installation geometry as well as structural performance.
50 mm Standard and Heavy Duty
The standard 50 mm, 50 × 50 mm row is listed at 21.5 kg/m². The separate heavy-duty 50 mm, 25 × 50 mm row is listed at 45.0 kg/m². The unit mass alone signals that they are not the same construction.
The heavy-duty row is heavier and needs a defined lift plan. A nominal 1220 × 3660 mm panel at 45.0 kg/m² is estimated at about 201 kg before packing and any surface addition. That is not a one-person panel, and it may also change the support erection and site access plan.
Why You Cannot Rank the Four Depths by “Strength”
A simple ranking from 25 to 50 mm can lead to a wrong quotation because it omits all the other variables:
- bar width and depth;
- mesh pitch and orientation;
- reinforcement and resin;
- support arrangement and bearing width;
- clear span and load footprint;
- acceptable deflection;
- cuts, openings and removable sections;
- surface or cover mass;
- required evidence.
Published manufacturer guidance also treats depth as an input to span and deflection rather than as a stand-alone capacity. Some suppliers estimate a shorter span for a shallow panel and recommend checking a deeper panel when the load, deflection or support spacing demands it. That reinforces a useful rule: let the support and service condition select the row, not the marketing phrase attached to the row.
A Longer Span Is Not Automatically Solved by One Depth Step
If a proposed panel fails the deflection limit, the response is not merely to “try 38 mm” or “go to 50 mm.” Check the product data for that exact row at the same span, load and deflection criterion.
A deeper section can help, but the table may describe a different bar construction, reinforcement or support assumption. If no matching data exists, the support spacing, panel split or design may need to change. Do not interpolate across depth or mesh rows.
Handling Can Decide Before Load Capacity Does
A full 1220 × 3660 mm panel with 38 × 38 mm mesh and 19.5 kg/m² unit mass is estimated at about 87 kg. The calculation is useful for planning, but the delivered piece weight should be confirmed for the actual resin, surface and size.
For a heavy-duty row, panel mass may exceed the handling method available on site. Dividing into cut pieces can improve handling, but the splits must preserve support, panel direction and opening requirements. The grating weight and panel net-weight guide explains how to keep unit mass, panel mass and packing weight separate.
A Practical Molded Grating Depth Selection Worksheet
Use the following sequence. It prevents a product depth from being selected before the design question is understood.
1. Mark the Actual Supports and Clear Spans
Show support centre lines, bearing faces, panel joints, free edges and any opening. Distinguish the delivered panel size from the unsupported distance.
2. State the Load and Its Contact Area
Say whether the load is pedestrian, point, line, wheel, trolley or equipment. Include its value and position. A uniform load does not describe a small equipment foot or a moving wheel if that contact is the governing case.
3. Set the Deflection Limit
Provide the project requirement, whether it is an absolute limit, a fraction of span, or both. The same panel row can pass one load case and fail another because of the permitted deflection.
4. State the Available Depth and Finished Envelope
Measure the frame, supporting steel or slab opening. Include the height added by a cover, clips or any required edge detail. A tight installation may remove a deeper candidate before the structural comparison starts.
5. Match a Complete Product Row
Identify depth, pitch, bar geometry, resin, surface and panel format. The molded grating size and weight guide separates pitch, net opening and panel size; the load and span guide explains the conditions behind structural data.
6. Check Handling and Fabrication
Calculate an approximate full-panel mass and compare it with the lifting and access method. Mark finished piece sizes, cut-outs and the expected maximum piece weight. If the product is cut, check that the remaining bars and local support still work.
7. Attach the Right Evidence
A sample does not prove the load of the supplied panel. A test report must correspond to the product, construction and test conditions. The quotation should identify the matched table, calculation or report and state any project condition still outside the evidence.
Put the accepted depth, actual section, resin, surface, size basis and evidence reference into the molded grating datasheet-to-order match before the configuration is released.
What Thickness Should You Start With?
There is no universal answer. These are practical starting points only:
- A supported shallow frame: Compare 25 or 30 mm rows when the installation depth is limited and matched support/load data exists.
- Typical construction pedestrian access: Review our 30 mm, 38 × 38 mm starting configuration, then confirm the actual project conditions.
- A frame with more available depth: Compare 38 mm products only when the same support and load case is available for each.
- A deeper standard 50 mm row: Use the 50 × 50 mm configuration as a candidate and check its mass, deflection and handling.
- A heavy-duty request: Treat the 50 mm, 25 × 50 mm row as a separate product and request matched structural evidence and a lifting plan.
- A tree-pit or architectural base: Use the appropriate 25 mm tree-pit configuration within its stated application, not as a generic platform rating.
What We Check Before Proposing a Depth
Our factory can produce and cut molded panels across the rows shown, but we do not convert a depth label into a universal capacity. The review keeps design, fabrication and commercial scope separate:
- We compare support and span before selecting a panel row.
- We identify standard, mini, directional and heavy-duty rows separately.
- We check full-panel mass and handling implications.
- We keep cutting, openings, edge treatment and clips in the quotation.
- We identify which load or test evidence matches the proposed configuration.
- We state when a required structural value remains to be confirmed.
This is important for a fair quotation. A 25 mm inquiry and a 50 mm heavy-duty inquiry may both say “molded grating,” while the manufacturing route, mass, panel lay-up, cutting plan and evidence requirement are different.
Factory review
From a Frame Drawing to a Molded Grating Depth
Our review follows the structure and handling constraints before it compares product rows.
We establish the supports, clear spans, bearing faces, available depth and finished envelope before comparing product rows.
The load type, contact footprint, position and permitted deflection are kept together, because one can govern even when the other appears acceptable.
Depth is compared only with the pitch, bar construction, resin and surface identified for each candidate. No row is ranked on depth alone.
We estimate the handling weight and review cuts, openings, edge treatment and piece identification against the site access method.
Load tables, calculations or reports must apply to the proposed construction and conditions. Values from a different row are not transferred by interpolation.
Manufacturer experience
What Our Factory Adds to the Depth Comparison
Product-row, cutting and handling knowledge sits beside the structural evidence, not in place of it.
Two 50 mm rows, two different products
The standard 50 × 50 mm row is listed at 21.5 kg/m². The 25 × 50 mm heavy-duty row is listed at 45.0 kg/m² and is quoted and evidenced separately.
Factory pedestrian starting point
Our 30 mm, 38 × 38 mm row is a known construction-access starting point. It remains subject to project support, load, deflection and exposure checks.
Full-panel handling is visible early
A nominal 1220 × 3660 mm panel at 19.5 kg/m² is estimated at 87 kg; the heavy-duty row is about 201 kg. Handling and access can change the piece split.
Samples compare configuration
A standard 3 × 3 cell sample helps compare mesh and surface. It does not prove which depth works over a project span.
Cutting and sealing are order scope
We coordinate factory cutting, drilling, requested edge sealing and clips with the panel choice. Edge sealing protects the cut; it does not restore a removed structural bar.
Evidence is configuration-specific
Our 2024 material-level report is not a load table for every 25, 30, 38 or 50 mm row. The proposed construction must match the evidence supplied.
RFQ checklist
What to Send for a 25–50 mm Molded Grating Review
Provide what is known and mark the values still to be confirmed. A marked drawing is enough to begin.
- Support and clear-span drawing — Show support lines, bearing faces, panel joints, unsupported edges, openings and the installation depth available.
- Load case and deflection limit — State load type, value, footprint, position, duration and the governing deflection criterion.
- Depth options under review — List 25, 30, 38 or 50 mm candidates only when the related pitch, construction, resin and surface can also be compared.
- Mesh and panel orientation — Provide both pitches, clear-opening requirement and the long-way-of-opening or bearing direction for directional products.
- Panel sizes and handling — Give finished dimensions, quantities, available access, lifting method and any maximum weight for one piece.
- Cuts, openings and fixing — Mark cutouts from fixed datums, edge treatment, drilled holes, removable areas, support material and clip requirements.
- Environment and surface — State chemicals, temperature, wash-down, fire, slip and color requirements before the structural row is quoted.
- Evidence required — Name the load table, calculation, test report, conformity document or inspection record required for acceptance.
Request a quote
Send Your Span, Load and Available Grating Depth
We will shortlist a molded row and identify the information needed for a comparable quotation.
- Depth compared with the complete panel row
- Panel mass and handling reviewed
- Matched evidence identified before quotation
Molded FRP Grating Thickness Questions
Is 50 mm molded grating always stronger than 38 mm?
Which molded grating depth is used for pedestrian walkways?
Does 25 mm grating suit every short-span access area?
Why do two 50 mm panels have different prices?
How much does a 1220 × 3660 mm molded grating panel weigh?
Can a sample show which thickness I need?
Can I use the same load table for 25, 30, 38 and 50 mm grating?